case 4716 - unit pick-list customer variant parsed as a number
UnitPickList.GetVariantCriteria put the value of a "customerid:<value>"
variant from the request into the query unparsed, reachable by any login
(security review F43, found during case 4712). The value is now parsed as a
long; anything else means no restriction, as 0 already did. The client's
format ("customerid: 5") still works.
Checked: new test fails on the old code, passes now; pick-list tests 10/10.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -139,8 +139,10 @@ namespace AyaNova.PickList
|
||||
switch (v[0])
|
||||
{
|
||||
case "customerid":
|
||||
if (string.IsNullOrWhiteSpace(v[1]) || v[1] == "0") return string.Empty;
|
||||
return $"aunit.customerid = {v[1]}";
|
||||
//case 4716: the id goes into the SQL, so it must be a number (anything else: no restriction, as for 0)
|
||||
if (!long.TryParse(v[1].Trim(), System.Globalization.NumberStyles.Integer, System.Globalization.CultureInfo.InvariantCulture, out long customerId) || customerId == 0)
|
||||
return string.Empty;
|
||||
return $"aunit.customerid = {customerId}";
|
||||
|
||||
}
|
||||
return string.Empty;
|
||||
|
||||
Reference in New Issue